
A TO Z OF Analytical Method Validation, Verification and Transfer
Develop the technical judgment needed to establish analytical procedure suitability, verify compendial methods, transfer procedures between laboratories, and manage specifications and atypical results using applicable FDA, USP, and ICH requirements.
Course overview
This course develops the technical judgment needed to establish analytical procedure suitability, verify compendial methods, transfer procedures between laboratories, and manage specifications and atypical results using applicable FDA, USP, and ICH requirements.
Why take this course
Analytical procedures underpin decisions about pharmaceutical quality, stability, and product acceptance. Their reliability depends on more than successful validation experiments. Instrument qualification, system suitability, compendial requirements, method performance, and laboratory conditions all influence whether analytical results are suitable for their intended purpose. These considerations become particularly important when established procedures are verified, transferred between laboratories, or used to support regulatory submissions.
This course connects analytical method validation, verification, and transfer with the supporting controls required throughout the analytical procedure lifecycle. Participants will examine FDA and USP requirements, ICH guidance, chromatographic system suitability, instrument qualification, and the selection of appropriate validation characteristics. The modules also address alternative procedures, analytical transfer approaches, specifications, and the evaluation of out-of-specification and out-of-trend results. Practical examples and case studies help participants connect technical requirements with laboratory decisions, from initial method assessment through continued use and regulatory compliance.
Eight modules · Nine hours
MODULE 1
- Seminar objectives review, expectations and scope.
- Drug Approval Process and Regulatory (FDA) Requirements (private standards)
- Pharmacopeias and Compendial (USP) Approval Process (public standards)
MODULE 2
- Compendial Harmonization Process
- Chromatography System Suitability Requirements
- Allowed Adjustments of Chromatographic System Parameters
MODULE 3
- Analytical Instrument Qualifications
- Instrument Categories
- Qualification Phases (DQ, IQ, OQ, PQ)
MODULE 4
- Analytical Method Validation (typical validation parameters)
- Specificity
- Precision/Accuracy
- Linearity/Range
- LOD and LOQ
MODULE 5
- Analytical Method Verification
- FDA and USP Requirements
- Factors to Consider
MODULE 6
- Analytical Method Transfer
- Different Approaches
MODULE 7
- Analytical Procedure Life Cycle
MODULE 8
- Setting Specifications FDA regulations and ICH guidelines (Q6A)
- Out-of-Specification (OOS)
- Out of Trend (OOT)
- How to handle OOS and OOT?
Designed for your role
Meet the faculty
Kelly Thomas has over two decades of hands-on cGMP experience in pharmaceutical and medical device manufacturing. Her expertise spans quality systems and validation activities, including analytical test methods, equipment, automated processes, computerized systems, and 21 CFR Part 11. She has managed complex industry projects using risk-based approaches and practical quality management principles across regulated manufacturing environments.